Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wpsh domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/navidtapeshcom/domains/navidtapesh.com/public_html/wp-includes/functions.php on line 6121

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the health-check domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/navidtapeshcom/domains/navidtapesh.com/public_html/wp-includes/functions.php on line 6121
Triton BTK – نوید طپش

Triton BTK

Below-The-Knee Balloon Catheter – Rx – 0.014″
“The effective 0.014″ to lower leg ischemia”

Designed to feature the unique aspects surrounding the anatomy and physiology of below-the-knee vessels such as smaller vessel diameter and the more sluggish flow pattern.

 
TECHNICAL DATA

Triton® BTK Bellow-The-Knee Peripheral Balloon Catheter – Rx & OTW – 0.014”

Mode of exchange: Rx & OTW
Balloon material/characteristic: modified polyamide / semi – compliant
Guidewire compatibility (max): 0.014”
Min. sheath compatibility (Rx): 4F ( Ø 2.0-3.5 mm)
5F ( Ø 4.0-5.0 mm)
Min. sheath compatibility (OTW): 4F
Radiopaque markers: 2 or 3, depending on balloon length (Pt-Ir)
Usable catheter length: 155 cm (Rx), 150 cm (OTW)
Distal shaft (Rx): 2.9F (Ø 2.0-2.5 mm)
3.2F (Ø 3.0-3.5 mm)
3.5F (Ø 4.0-5.0 mm)
Shaft profile (OTW): 3.6F (Ø 2.0-5.0 mm)
Hypotube: 2.6 Fr
Nominal pressure: 8 atm
Rated Burst Pressure: 16 atm
Coating: Hydrophilic, HiFlow
Total shelf life: 4 years

  • Short, flexible and tapered tip 0.016’’ (lowest in class)  engineered to promote easier navigation since  occlusions are more prevalent than stenoses in  below-the-knee cases
  • Lowest in class balloon crossing profile trackability to the most challenging lesions with ease and  confidence
  • 0.014’’ guidewire compatibility for excellent  crossability
  • 2 Platinum-Iridium marker bands for the lengths of 90-120-150 mm provide excellent  placement accuracy
  • Third Platinum-Iridium marker band is centered on the 180 & 210 mm balloon lengths,  providing additional visibility
  • Tri-folding balloon technology for optimal refoldability
  • Proprietary hydrophilic coating, HiFlow

Indications for Use:
Triton BTK is intended for PTA, including the:
• descending genicular arteries
• lateral superior genicular arteries
• popliteal arteries
• lateral inferior genicular arteries
• anterior tibial arteries
• peroneal arteries
• posterior tibial arteries
• dorsalis pedis arteries
• lateral plantal arteries
• lateral tarsal arteries
• arcuate arteries