Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wpsh domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/navidtapeshcom/domains/navidtapesh.com/public_html/wp-includes/functions.php on line 6121

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the health-check domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/navidtapeshcom/domains/navidtapesh.com/public_html/wp-includes/functions.php on line 6121
Europa Ultra – نوید طپش

Europa Ultra NC

Non-Compliant Balloon Catheter

” The superior high force for the demanding Interventionalist ”

Low profile, high pressure angioplasty catheters designed to be used in dilating the unyielding fibrocalcified lesions with a high pressure application providing controlled expansion, as well.

The use of Europa Ultra NCTM for post-dilatation of DES/or BMS optimizes stent-to-wall apposition, reduces edge effects and minimizes vessel wall damage post stenting, even in stiff fibrotic lesions

TECHNICAL DATA

Europa Ultra NCTM Non-Compliant Coronary Balloon Catheter

Mode of exchange: Rx
Baloon material / characteristic: modified polyamide / non-compliant
Guiding Catheter compatibility (min): 5F
Usable Catheter length: 140 cm
Radiopaque markers: 2, Pt-Ir
Distal shaft: 2.4F (Ø 2.00 mm)
2.5F (Ø 2.25 – 3.50 mm)
2.9F (Ø 4.00 – 5.00 mm)
Hypotube: 2.0F
Guidewire compatibility (max): 0.014”
Nomimal pressure: 10 atm
Rated Burst Pressure: 18 – 20 atm
Coating: Hydrophilic, HiFlow
Total shelf life: 4 years

 

Improved trackability

  • Ultra-low 0.016’’ entry profile of Rontis’ soft, short and tapered atraumatic tip ensures safe access
  • Proprietary ironing process ensures ideal refoldability
  • Tip-to-wire conformance along with  controlled steering from hand-to-tip for  excellent torqueability
  • Rontis’ proprietary high performance materials contribute to lower shaft profiles
  • Integrated shaft-hypotube transition ensures 1:1  pushability
  • Laser-bonding technology at critical flex points provides a balance of seamless and flexible transition
  • 2 Platinum-Iridium marker bands presenting the distal and proximal balloon shoulders provide higher radiopacity
  • Controlled balloon expansion for accurate dilatation of arteries, therefore minimizing the possibility for artery damage

Lubricity

  • Rontis’ proprietary hydrophilic coating, HiFlow ensures smoother navigation through even the most challenging and tortuous vasculature
Europa Ultra NC